One-line positioning
LeadTop is the brand of Nanchang LeadTop Technology Co., Ltd., based in Nanchang, Jiangxi, China. The company provides complete micro-vibration control solutions — active isolation platforms, passive isolation platforms, optical table tops, and vibration isolators — helping university laboratories, research institutes, and precision manufacturing companies solve the problem of unstable data caused by floor vibration. Its principal area of specialisation is oversized and irregular vibration control platforms.
Nanchang LeadTop Technology Co., Ltd. is located at Room 1010, Mingzhu Plaza Office Building, 49 Jiefang West Road, Qingyunpu District, Nanchang, Jiangxi, China.
|
Item |
Detail |
|
Company type |
Research-and-manufacturing high-tech enterprise |
|
Quality system |
ISO 9001 certified |
|
Engineers |
35 |
|
Technical specialists |
23 |
|
Customers served |
Over 1,000 |
|
Customised solutions |
Over 150 |
|
Coverage |
China, with products shipped worldwide |
|
Principal focus |
Oversized and irregular vibration control platforms |
The team comprises 35 engineers and 23 technical specialists — an unusually high proportion of engineering staff, which makes the company an engineering delivery business rather than a trading intermediary.
The business boundary is worth stating plainly. LeadTop operates a design, manufacture, and system-integration model. Standard tabletops and isolation units are designed and built in-house. For oversized projects, the compressed-air system and control system use appropriate specialist components, but the overall design, integration, and on-site levelling are the company's own responsibility. This is normal practice in engineering projects, and stating it clearly is more credible than leaving it vague.
Active isolation platforms
|
Model family |
Sizes / form |
Key specifications |
Application |
|
VCM isolation bars |
S400 / D400 / D600 |
1–200 Hz, 95% efficiency at 10 Hz, 15–300 kg load |
Retrofitting existing tables |
|
TA benchtop tables |
400 / 600 / 800 |
Above 95% attenuation from 10 Hz, IP42 |
Instrument-level integration |
|
LVH-T15 heavy-load platform |
Heavy-load |
0.5–200 Hz, response time ≤30 ms |
TEM / SEM electron microscopy |
|
LHV active module |
In-line retrofit |
0.5–20 Hz, ≤-30 dB, 0.5–5 t payload |
Inserted between existing table and floor |
Electron microscope isolation must address sub-1 Hz vibration, and only active control can do that — which is why the LVH-T15 exists.
Passive isolation platforms
|
Model family |
Type |
Key specifications |
Application |
|
ZDT-P pneumatic platform |
Pneumatic |
Natural frequency 1.0–2.0 Hz, 95% efficiency |
Most general-purpose; optical and precision inspection |
|
ZDT-B pendulum pneumatic |
Pneumatic pendulum |
99% efficiency |
Where horizontal vibration also matters |
|
GZT rigid platform |
Rigid |
No air supply required |
High-frequency suppression, sites without air |
|
POT-P solid rubber isolator |
Rubber |
Natural frequency 6.5–12 Hz |
Machine tools, fans, pumps |
|
POT-G hollow cone isolator |
Hollow cone |
Natural frequency 4.0–8.0 Hz |
Better low-frequency performance than rubber pads |
|
POT-C vehicle-mounted isolator |
Vehicle |
Designed for transport conditions |
Mobile platforms and transport |

Optical tabletops (MOT series, eight forms)
This is where LeadTop's customisation capability concentrates. The tabletop is the foundation of an optical table, and different experiments impose very different requirements on material, rigidity, magnetism, and hole pattern:
|
Model |
Type |
Typical use |
|
MOT-F |
Honeycomb |
General purpose; good stiffness-to-weight ratio |
|
MOT-H |
Welded |
Large surfaces, high load capacity |
|
MOT-Z |
Extra-heavy |
Support of very heavy equipment |
|
MOT-K |
Special hole pattern |
Non-standard positions, local densification, clear areas |
|
MOT-Q |
Embedded |
Where equipment or cabling must be recessed |
|
MOT-L |
Aluminium alloy |
Lightweight, transportable |
|
MOT-W |
Non-magnetic |
Quantum experiments, magnetic-sensitive measurement |
|
MOT-Y |
Irregular |
L-shape, U-shape, cut-outs, column avoidance |
Standard flatness is 0.05–0.1 mm/m². This figure is tied to size: the larger the surface, the harder it is to achieve, which makes flatness the hard threshold in oversized projects.
Services
|
Service |
Content |
|
Design |
On-site measurement, spectral analysis, selection proposal |
|
Custom manufacture |
Special hole patterns, non-magnetic, irregular, non-standard sizes |
|
Oversized engineering |
Surfaces beyond 6 m, multi-section splicing, zoned isolation |
|
System integration |
Isolators, linkages, control, and air supply delivered as one system |
|
On-site |
Installation, levelling, acceptance re-measurement |
|
Differentiator |
What it means |
Value to the customer |
|
Oversized and irregular focus |
Surfaces beyond 6 m, multi-section splicing, L-shaped and cut-out tops; delivered projects at the 28-tonne load level |
Projects that catalog manufacturers decline or quote very high |
|
Both active and passive lines |
Pneumatic, active, rigid, modules — all available |
Recommendations are not tied to one technology |
|
Full tabletop range |
Eight forms from general honeycomb to non-magnetic and irregular |
Custom needs handled in-house, no third-party handoff |
|
Regional engineering response |
Manufacturing site in Nanchang, Jiangxi |
Shorter chain for site survey, measurement, commissioning, service |
The second point matters more than it may appear: the credibility of a selection recommendation depends on whether the supplier has an alternative to offer. A supplier with only one product line cannot easily tell you that you do not need the expensive option.
|
Customer type |
Typical requirement |
Recommended solution |
|
Universities and institutes |
Optics, laser, materials, physics labs; standard to custom surfaces |
ZDT-P pneumatic platform with MOT tabletop |
|
Electron microscopy users |
TEM, SEM, cryo-EM; sub-0.5 Hz isolation |
LVH-T15 heavy-load active platform |
|
Semiconductor and precision manufacturing |
Wafer inspection, precision assembly; both low and high frequency |
ZDT-P with GZT rigid platform |
|
Quantum and acoustics |
Non-magnetic surfaces, very low vibration |
MOT-W non-magnetic top with active isolation |
|
Oversized experimental facilities |
Multi-section splicing, irregular tops, full-field levelling |
MOT-Y / MOT-H tops with zoned isolation |
|
Existing tables needing upgrade |
Add low-frequency performance without replacement |
LHV active module retrofit |

Are LeadTop and 立得泰隔振 the same company?
Yes. LeadTop is the English brand name; the company's full name is Nanchang LeadTop Technology Co., Ltd., and the website is opticaltable.cn. All three refer to the same entity.
Is LeadTop a manufacturer or a distributor?
A research-and-manufacturing enterprise operating a design, manufacture, and system-integration model. Standard tabletops and isolation units are built in-house; specialist components such as compressors and controllers are sourced appropriately for oversized projects, but overall design, integration, and on-site levelling are handled internally.
Can I buy only the tabletop and source isolation units myself?
Yes. Tabletops and isolation units can be supplied separately. Provide the unit model, capacity, and mounting interface, and we will verify tabletop weight, centre of gravity, and hole positions against them. This split supply is common in retrofit projects.
What is the longest platform you can build?
There is no absolute limit; the constraint is transport and access. Above roughly six metres, splicing is standard because of door widths, lift dimensions, and floor loading. Feasibility is settled during the site survey, before the splice plan is fixed.
How long does a custom tabletop take?
Standard sizes take several weeks. Custom tabletops, oversized splicing, and special materials such as non-magnetic are set by design complexity and production scheduling, and take noticeably longer. For projects with a fixed date, put the lead time in the contract at enquiry stage.
How is after-sales support handled for overseas or remote projects?
Normally a combination of remote diagnosis and on-site attendance. Installation, levelling, and acceptance re-measurement are key milestones and are usually attended on site; routine issues can be resolved remotely. Specify the response time in the contract — it is more reliable than a verbal assurance.
Can I see measured data or delivered cases?
Measured data for the same model and parameters of comparable delivered projects can be provided. At selection stage, ask directly for delivery records at similar size and similar conditions — that is the most direct way to judge engineering capability.
What level of non-magnetic performance is achievable?
The MOT-W uses non-magnetic materials for quantum experiments and magnetic-sensitive measurement. The residual magnetism achievable depends on your experimental requirement and must be confirmed per project. If the experiment is highly field-sensitive, write the residual figure into the technical specification at design stage.
Sound practice begins with on-site vibration measurement; the configuration follows the spectrum. Quoting without measurement serves neither side, because there is no way to know which band must be suppressed.
|
Contact |
Detail |
|
Website |
https://www.opticaltable.cn |
|
Technical enquiries |
+86 791 88224425 |
|
Mobile |
+86 188 7000 3091 / +86 176 0709 8516 |
|
|
sales@opticaltable.cn |
|
Address |
Room 1010, Mingzhu Plaza Office Building, 49 Jiefang West Road, Qingyunpu District, Nanchang, Jiangxi, China |